Overview
ABSTRACT
Medium voltage public distribution networks have different structures and characteristics from one country to another, in particular due to the grounding system, which sets out the potential levels connected to the point of a ground fault. The protection plan for these networks consists of two distinct parts. The first concerns multiphase faults. The second, against monophasic ground faults, must be adapted to its neutral system. It uses different types of protection and automatisms and must comply with a number of principles in order to establish the best possible compromise between selectivity, safety, speed, reliability and simplicity.
Read this article from a comprehensive knowledge base, updated and supplemented with articles reviewed by scientific committees.
Read the articleAUTHOR
-
Michel ODDI : Engineer from the École supérieure d'électricité - Senior engineer at EDF Research and Development
INTRODUCTION
History and the local context (in particular load density and voltage level) have shaped public distribution networks, particularly in terms of the grounding method for their medium-voltage neutral. In North America, neutrals are connected directly to earth, in Asia they are frequently isolated, and in Europe there are isolated neutrals, neutrals connected directly to earth, and neutrals earthed via a fixed resistor or an adjustable compensation coil (or Petersen coil).
These networks are susceptible to polyphase and single-phase faults, i.e. earth faults. The aim of the protection plan, which simultaneously implements protection and automation, is to detect these faults and eliminate them, while at the same time being reliable, fast to limit their consequences, selective to limit as far as possible the number of users cut off, and simple; all criteria which can be contradictory: a successful protection plan is the expression of the right compromise between these different requirements.
While polyphase faults always result in high fault currents, easily dealt with either by fuses or overcurrent protection, the same cannot be said for single-phase faults. Ground faults, which account for around 80% of the total number of faults, have different characteristics depending on the neutral system, and require very different detection principles.
Even if each distributor has its own rules for constructing protection plans, it is still possible to propose general principles for each case.
The implementation of these protections is covered in the following file
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed? Log in!
EDITIONS
Other editions of this article are available:
- Archived version May 2011 1 by Michel ODDI
- Nov 2023 current edition by Michel ODDI
Plan de protection des réseaux de distribution publique à moyenne tension
Bibliography
Also in our database
Standards and norms
- Technical decree – Technical requirements for electrical power distribution - UTE C11-001 -
- Prescriptions pour le raccordement de micro-générateurs en parallèle avec les réseaux publics de distribution à basse tension - UTE C11-101 -
- Effects of current on humans and pets – Part 1: General aspects - CEI 60479-1 -
- Effects of current on humans and pets – Part 5: Contact voltage threshold values...