2. Cerebrovascular imaging devices using two-photon microscopy
As mentioned above, one of the most relevant devices for intravital
microscopy is the two-photon microscope. In biomedical research and
preclinical animal studies, this microscope consists of an upright
stand, a pulsed infrared (IR) laser source and an IR-optimized scanner
(figure 2). Unlike
its confocal counterpart, the biphotonic nature of the excitation
means that a pin-hole diaphragm is not required to select the fluorescence
emitted at the focal plane of the objective. The five main manufacturers
of multiphoton microscopes are Zeiss (LSM 7MP), Olympus (Fluoview
®), Nikon (A1R MP), Leica (TCS MP5, TCS SP8 MP) and LaVision BioTec
GmbH (TriMScope II). In...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Cerebrovascular imaging devices using two-photon microscopy
Bibliography
-
(1) - KIM (S.G.) - Perfusion MR imaging : evolution from initial development
to functional studies. - Neuroimage, 62(2), p. 672-675
(2012).
-
(2) - KLEINFELD (D.), MITRA (P.P.), HELMCHEN (F.), DENK (W.) - Fluctuations and stimulus-induced changes
in blood flow observed in individual capillaries in layers 2 through
4 of rat...
Also in our database
-
ROBLIN (G.) - Microscopies optiques à balayage. - [R 6 714]...
Software tools
Free software for image processing and analysis:
ImageJ http://rsb.info.nih.gov/ij/
FIJI image http://fiji.sc/Fiji
Events
Spie Photonics West World Congress on (Bio)Photonic Imaging: this
congress is held every year on the east coast of America (http://spie.org/x2584.xml).
The European variant SPIE Photonics Europe http://spie.org/x12290.xml
École thématique Microscopie Fonctionnelle en Biologie (Mifobio):
this...
Standards and norms
- Laser
safety – Part 1: Equipment classification, specifications and user
guide - EN 60825-1/A2 -
Regulations
Directive 2010/63/EU of the European Parliament and of the Council
of 22 September 2010 on the protection of animals used for scientific
purposes.
Arrêté du 1er février 2013 fixant les conditions d'agrément,
d'aménagement et de fonctionnement des établissements utilisateurs,
éleveurs ou fournisseurs d'animaux utilisés à des fins scientifiques
et leurs contrôles (NOR: AGRG1238753A).
Patents
MONNEREAU (C.), ANDRAUD (C.), MAURY (O.). – Novel water-soluble
chromophore. PCT Int. Appl. WO 2013011242 A1 20130124 (2013).
Directory
Manufacturers – Suppliers – Distributors (non-exhaustive list)
Microscopes :
Zeiss http://microscopy.zeiss.com/microscopy/en_de/products/confocal-
microscopes/lsm-7-mp.html
Olympus
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!