10. Compulsory administrative formalities
-
News
All modifications to the facades of residential buildings, or the creation of new surface areas, are subject to administrative authorizations. Designers and architects are familiar with these procedures. However, if any part of the building is classified as an ERP (common premises of a tourist residence, ground-floor shops, common premises of a home for the elderly, etc.), these ERP premises must now be the subject of a special administrative application for all interior modifications. This application is drawn up using Cerfa document N° 13824*02 entitled "Demande d'autorisation de construire, d'aménager ou de modifier un Établissement recevant du public (ERP)". This document, which meets the requirements of article L. 111-8 of the French Construction and Housing Code, is used if you wish to build, fit out or modify an establishment open to the public in all cases....
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Compulsory administrative formalities
Bibliography
-
(1) - DU BELLAY (J.C.) - Règlement en sécurité incendie dans les bâtiments d'habitation. – - Éditions du Moniteur (2009).
-
(2) - DU BELLAY (J.C.) - Règlement en sécurité incendie dans les bâtiments soumis au code du travail. – - Éditions du Moniteur (2007).
-
(3)...
Also in our database
-
ENGEL (P.) - Réparations et mise au norme incendie, - [C 6 301]...
Software tools
CISIA June 2000 The Bayesian (version for Windows Vista).
Websites
Cerib laboratory – Concrete research
http://www.cerib.com
CSTB – Centre Scientifique et Technique du Bâtiment
http://www.cstb.fr
CTICM – Centre technique industriel de la construction métallique
http://www.cticm.com
...
Events
Batimat Reed Expositions – International construction show, held every two years in Paris (odd-numbered years).
http://www.batimat.com
Standards and norms
- Installations de branchement à basse tension. - NF C 14-100 - 09-1998
- Installations électriques à basse tension. - NF C 15-100 - 12-2002
- Degrés de protection procurés par les enveloppes (code IP) (équivalente à NF EN 60529 de juin 2000). - NF C 20-010 - 10-1992
- Fabrication de portes en bois. - NF P 23-501 et 502 -
- Colonnes sèches. - NF S 61-750 - 07-1973
- Fire safety systems (SSI)...
Regulations
The main general texts in force governing safety in residential buildings are as follows.
Town Planning Code
Art. L. 421-3: "Building permits may only be granted... if the applicant undertakes to comply with the general building regulations defined in article L. 111-3."
Art. L. 111-3: sets out "the general construction rules and maintenance measures intended to ensure compliance with safety regulations until the...
Directory
Manufacturers – Suppliers – Distributors (non-exhaustive list)
Horizontal electric injection molding machines
Arburg SAS Hawaii distributed by Arburg France
http://www.arburg.fr
Organizations – Federations – Associations (non-exhaustive list)
OPPBT Organisme professionnel de prévention du bâtiment et des travaux publics (Professional...
Statistical and economic data
Organisme professionnel de prévention du bâtiment
-
New dimensions for stretcher passage on stairs
The minimum dimensions of staircases in residential buildings must comply with the requirements set out in article R. 111.5 of the French Construction and Housing Code, bearing in mind that the dimensions of a stretcher are standardized (NF EN 1865), with an unfolded length of 1.97 m and a width...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!