4. Application to reinforced wooden beams
Thirty glued-laminated timber (glulam) beams of dimensions 2300×130×90 mm3 were tested for the study. Twenty beams were strengthened with a partially compressed high-performance mortar plate, while the other ten served as control test bodies. Of the twenty reinforced beams (BLC + CFC), ten were also fitted with carbon FRP reinforcement in the tension zone (BLC + CFC + FRP). The CFC reinforcement element is 40 mm thick and 90 mm wide, its length being equal to the total length of the timber beam. The total length of the beams is 2.3 m, with a clear span of 2 m.
CFC elements and glulam beams are assembled using an epoxy glue, the technical specifications of which can be found at 5. This glue is also used to ensure the...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Application to reinforced wooden beams
Bibliography
-
(1) - AL-MAHMOUD (F.), CASTEL (A.), RAOUL (F.), TOURNEUR (C.) - RC beams strengthened with NSM CFRP rods and modeling of peeling-off failure. - Composite Structures July 2010; 92;8;1920-1930.
-
(2) - DE LORENZIS (L.), NANNI (A.) - Characterization of FRP rods as near surface mounted reinforcement, - J Compos Construct ASCE 2001:...
Also in our database
-
MAMILLAN (M.) - Restauration des bâtiments en béton armé. - ...
Patents
FERRIER (E) Structural Element Comprising Wood And Concrete (2010), FR2009/001303
Websites
Official Website for International Institute for FRP in construction https://www.iifc.org/about/
Composite bridge http://www.cobrae.org
Events
European Construction Composites Day http://www.jeccomposites.com
Directory
Civil and Environmental Engineering Laboratory LGCIE https://www.insa-lyon.fr/fr/mots-cl%C3%A9s/lgcie