7. Dosage of additives
Dosages vary widely. General indications are as follows:
plasticizers: 0.2 to 0.5% of cement weight per cubic metre of concrete;
superplasticizers: 0.5 to 3% ;
gas pedals: 0.5 to 3% ;
retardants: 0.15 to 2% ;
water repellents: 0.2 to 2% ;
air entrainers: 0.02 to 0.2%.