7. Conclusion
Pouring fresh concrete against existing hardened concrete is a common operation in building construction and civil engineering. It is an application that is encountered at every construction joint. Based on this principle, reinforcement with layers of concrete has been gaining importance in recent years due to the growing need for rehabilitation and renovation of existing structures.
Of course, when designing these structural elements, the transfer of internal forces across the transfer surface (the interface between the new and old concrete) is a critical factor in the dimensioning process.
For this reason, a new design and dimensioning method has been developed based on shear tests specifically carried out for this purpose and for different types of surface treatments. Several applied research projects have thus contributed to the development of concrete connectors (studs) and this...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Conclusion
Bibliography
-
(1) - FIB - Code modèle de la FIB pour les structures en béton - (2010).
-
(2) - BIRKELAND (P.W.), BIRKELAND (H.W) - Connections in precast concrete construction, - American Concrete Institute, Journal of the American Concrete Institute, Vol. 63, No. 3, pp. 345-368, mars 1966.
- ...
Also in our database
-
REGNIER (F.) - Fixation par chevillage dans la construction en béton. - [C 962]...
Standards and norms
- Characterization of pavement texture using surface profiles – Part 1: Determination of mean profile depth - EN ISO 13473-1 - 2019
- Products and systems for the protection and repair of concrete structures. Test methods Measurement of bond strength by pull-off - EN 1542 - 1999
- Design and requirements for construction works of post-installed shear connection for two concrete layers, EOTA - TR 066 - novembre...
Regulations
Decree of October 22, 2010 on the classification and seismic construction rules applicable to buildings classified as "normal risk"
Seismic design of non-structural elements in buildings – Seismic justification for buildings at "normal risk," Ministry of Ecology, Sustainable Development, and Energy, and Ministry of Housing, Territorial Equality, and Rural Affairs, 2014
Directory
Manufacturers – Suppliers – Distributors
PROFIS Engineering, [Software] HILTI France.
https://profisengineering.hilti.com/
Organizations – Federations – Associations
National Union of Contractors Specializing in Structural Repair and Reinforcement (STRRES)
http://www.strres.org
...