9. Elevators
-
In compliance with standard NF P 82-210 :
they are not considered as a means of evacuation, except in the case of homes for the disabled;
they must always be accessible from the common areas; if the elevator is private, it must be double-service (door on the dwelling side with the same fire rating as the shaft + door from a common circulation);
They must be separated from parking lots and basement cellars by an airlock.
-
Priority elevators (required for 4th family)
In compliance with standard NF P 82-207 (April 1976), they feature :
-
a control device with :
a level of access for firefighters,
two-position switch with 6 mm square socket, 10 mm deep (special fire department key) ;
a...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Elevators
Bibliography
-
(1) - DU BELLAY (J.C.) - Règlement en sécurité incendie dans les bâtiments d'habitation. – - Éditions du Moniteur (2009).
-
(2) - DU BELLAY (J.C.) - Règlement en sécurité incendie dans les bâtiments soumis au code du travail. – - Éditions du Moniteur (2007).
-
(3)...
Also in our database
-
ENGEL (P.) - Réparations et mise au norme incendie, - [C 6 301]...
Software tools
CISIA June 2000 The Bayesian (version for Windows Vista).
Websites
Cerib laboratory – Concrete research
http://www.cerib.com
CSTB – Centre Scientifique et Technique du Bâtiment
http://www.cstb.fr
CTICM – Centre technique industriel de la construction métallique
http://www.cticm.com
...
Events
Batimat Reed Expositions – International construction show, held every two years in Paris (odd-numbered years).
http://www.batimat.com
Standards and norms
- Installations de branchement à basse tension. - NF C 14-100 - 09-1998
- Installations électriques à basse tension. - NF C 15-100 - 12-2002
- Degrés de protection procurés par les enveloppes (code IP) (équivalente à NF EN 60529 de juin 2000). - NF C 20-010 - 10-1992
- Fabrication de portes en bois. - NF P 23-501 et 502 -
- Colonnes sèches. - NF S 61-750 - 07-1973
- Fire safety systems (SSI)...
Regulations
The main general texts in force governing safety in residential buildings are as follows.
Town Planning Code
Art. L. 421-3: "Building permits may only be granted... if the applicant undertakes to comply with the general building regulations defined in article L. 111-3."
Art. L. 111-3: sets out "the general construction rules and maintenance measures intended to ensure compliance with safety regulations until the...
Directory
Manufacturers – Suppliers – Distributors (non-exhaustive list)
Horizontal electric injection molding machines
Arburg SAS Hawaii distributed by Arburg France
http://www.arburg.fr
Organizations – Federations – Associations (non-exhaustive list)
OPPBT Organisme professionnel de prévention du bâtiment et des travaux publics (Professional...
Statistical and economic data
Organisme professionnel de prévention du bâtiment
-
New dimensions for stretcher passage on stairs
The minimum dimensions of staircases in residential buildings must comply with the requirements set out in article R. 111.5 of the French Construction and Housing Code, bearing in mind that the dimensions of a stretcher are standardized (NF EN 1865), with an unfolded length of 1.97 m and a width...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?