2. Micropore characterization
To begin with, it should be noted that micropores fill at very low relative pressures, sometimes as low as 10–7 w/w 0, which corresponds to a nitrogen equilibrium pressure of 10–4 mbar. To be able to highlight microporosity, it is therefore necessary to ensure that the apparatus used enables reliable measurements to be made at these low pressures. This requires not only a 0 to 1 mbar pressure gauge, but also a device that is sufficiently tight to obtain a static vacuum for the duration of the measurements. Moreover, the smaller the micropores, the longer it takes to reach equilibrium, since diffusion of nitrogen is slow at 77 K. The operating mode chosen should enable a compromise to be found to take account of the equipment's performance....
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Micropore characterization
Bibliography
-
(1) - ROUQUEROL (F.), ROUQUEROL (J.), SANG (K.S.W.), LLEWELLYN (P.) - Adsorption by powders and porous solids : principles, methodology and applications. - 2nd Edition, Academic Press, 626 p. (2014).
-
(2) - THOMMES (M.), KANEKO (K.), NEIMARK (A.V.), OLIVIER (J.P.), RODRIGUEZ-REINOSO (F.), ROUQUEROL (J.S.W.), SING...
Also in our database
-
ROUQUEROL (F.), ROUQUEROL (J.), BEURROIES (I.), LLEWELLYN (P.), DENOYEL (R.) - Texture des matériaux divisés. Aire spécifique des matériaux pulvérulents ou nanoporeux. -
Software tools
Database of hundreds of adsorption isotherms, including many new adsorbents http://adsorbents.nist.gov/
NLDFT calculations http://www.NLDFT.com
Fluid properties https://www.nist.gov/srd/refprop
Events
On a national scale: annual days of the French Adsorption Association, usually in January-February. http://www.adsorption.fr/spip.php?rubrique1
Internationally: three successive triennial congresses, one per year, usually in April-May, in the following order:
Standards and norms
- Pore size distribution and porosity of solid materials by mercury porosimetry and gas adsorption – Part 2 : Analysis of mesopores and macropores by gas adsorption - ISO 15901-2 - 2006
- Pore size distribution and porosity of solid materials by mercury porosimetry and gas adsorption – Part 3 : Analysis of micropores by gas adsorption - ISO 15901-3 - 2007
Directory
Marketed equipment (non-exhaustive list)
The commercial adsorption units shown in Table allow a detailed study based on the nitrogen adsorption-desorption isotherm at 77 K. Generally speaking, the adsorption isotherm domain they automatically record, and the software they are equipped with, allow fairly easy access to specific surface area (BET method
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!