3. Case study
Here's how a diagnosis was carried out on a motorized fan unit at an incineration plant in the Paris region, driven at 2,420 rpm by a 300 kW motor and pulley-belt transmission.
The values measured during a periodic inspection show that, on the motor bearing on the pulley side, the alarm threshold defined for the global indicator "RMS speed" standardized to 10/1,000 Hz has been exceeded. The value of this global indicator, measured in the horizontal radial direction, has risen from 3.9 to 12.2 mm/s since the last collection, whereas it remains more or less stable on the other fan bearings and on the vertical radial measurements of the bearing in question.
...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Case study