3. Application to surface characterization
The concept of surface is always difficult to define. In the case
of a pure, perfectly prepared material, the surface can be considered
as the region of the sample affected by the presence of an atmosphere,
a medium or a vacuum. This very general but restrictive definition
is used in specific fields (e.g. chemisorption, catalysis) where only
high-resolution methods are used, generally under ultra-high vacuum.
In the case of an industrial product, it is easy to see that its surface
composition differs from its core composition to depths that are sometimes
very great, requiring other means of investigation.
Generally speaking, industrial surfaces
are highly complex, because at each stage of the process, the characteristics
are linked not only to the last tool used, but also to the preceding
stages. Even on the basis of a simplified schematic model, such as
that described...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Application to surface characterization
Bibliography
-
(1) - MOLLER (P.), NIELSEN (L.P.) - Advanced Surface Technology :
A holistic view on the extensive and intertwined world of applied
surface engineering. - NASF Vol. 2, Chap. 36.9,
pp. 1051-1055 (2013).
-
(2) - BINGHAM (R.V.) &
al - Novel use of glow discharge optical emission
spectroscopy (GDOES) to study corrosion...
Also in our database
-
LAUDE (J.P.), CHAPON (P.) - Spectroscopie de décharge luminescente
(GDOS et GDMS). - [P 2 715]...
Event
"GD day", international LDS conference, every two years (even-numbered
years)
http://www.gd-day.com
Standards and norms
- ISO Surface
chemical analysis – Glow discharge optical emission spectrometry (GD-OES)
– Introduction to use. - ISO 14707 -
- ISO Surface
chemical analysis – Analysis of zinc and/or aluminium based metallic
coatings by glow-discharge optical-emission spectrometry. - ISO 16962 -
Patents
Glow discharge spectrometric measurement of an organic or polymeric
solid sample. EP 24434275A1.
Device example
Features of the Horiba Jobin-Yvon GD-Profiler 2 spectrometer
The device is built around a 47-channel simultaneous polychromator
with a 2,400 tr/mm double-order concave holographic grating, 0.5 m
focal length and 18 to 25 pm resolution in the 110 to 600 nm spectral
range. In the UV, the elements measured are H (and D, deuterium, an
isotope of H), O, C, N, Cl, Br, I.
The optical system can also include an additional polychromator...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?