Equipment flow rate and head are the main parameters defining the project. The installed power P (expressed in kilowatts) is calculated using the formula :
P = k · Q
e
· h
with :
k
:
a coefficient depending on the overall efficiency of the plant, taking into account pressure losses along the hydraulic circuit and overall plant efficiencies (k "8)
Q
e
:
equipment flow rate...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
This offer includes interactive articles. Their quizzes highlight the key information to remember and validate their acquisition: from reader to player, you can enrich your knowledge.
You can easily identify them thanks to this pictogram: