Equipment flow rate and head are the main parameters defining the project. The installed power P (expressed in kilowatts) is calculated using the formula :P = k · Qe · h
with :
k
:
a coefficient depending on the overall efficiency of the plant, taking into account pressure losses along the hydraulic circuit and overall plant efficiencies (k "8)
Q e
:
equipment flow rate (m3/s)
h
:
gross height (m).
The annual producibility Wpm...