4. Coating application
Generally speaking, the rules of the art require :
apply a coating to a substrate with a moisture content of less than 5% by weight (tested using a moisture meter), otherwise the film will rapidly deteriorate (blistering and flaking in particular);
not to work when climatic conditions do not allow it: temperatures below 10°C or above 25°C, humidity > 80% RH, high winds, etc.
SCROLL TO TOP
...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Coating application
Bibliography
-
(1) - BERTHIER (J.) -
Diffusion de vapeur au travers des parois. Condensation.
-
Sciences du Bâtiment CSTB, REEF Vol. II, pp 13-18 (1980).
-
(2) - CAUSSARIEU (A.), GAUMART (T.) -
Guide pratique de la rénovation...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!