4. Measurement of electrostatic charge and charge distribution
It is recognized that either the charge distribution or the mass charge of particles plays an important role in their behavior. The presence of bipolar charges can reduce deposition efficiency in electrostatic coating processes. In the powder conveying industry, the presence of bipolar charges leads to fouling and electrostatic discharges, as well as ignition risks. It is therefore essential to have methods for qualifying and/or quantifying the polarity and level of electrostatic charges present within powder particles. This objective can be achieved by various devices described below.
The Faraday cage (figure ) is one of the most common devices for measuring powder charge. A Faraday cage consists of two concentric cylinders separated by an insulator. The product whose...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Measurement of electrostatic charge and charge distribution
Bibliography
-
(1) - TEUNOU (E.), FITZPATRICK (J.-J.) - Effect of storage time and consolidation on food powder flowability. - Journal of Food Engineering, 43, p. 97-101 (2000).
-
(2) - RUMPF (H.) - Particle technology. - Chapman and Hall (1979).
-
(3)...
Also in our database
-
SALEH (K.), GUIGON (P.) - Mise en œuvre des poudres. Caractérisation et analyse des propriétés des solides divisés. -
Events
Science et Technologie des Poudres (STP) et Matériaux frittés Triennial Symposium. May 27-29, 2009, Montpellier.
Société Française du Génie des Procédés (SFGP) biennial congress. October 14-16, 2009, Marseille.
World Congress on Particle Technology Congress held every 3-4 years. April 26-29, 2010, Nuremberg, Germany.
International Congress on Particle Technology (PARTEC) Annual Congress (Nuremberg, Germany). April 26-29,...
Standards and norms
- Code of practice for Control of undesirable static electricity. Part 2 : Recommendations for particular industrial situations - BS 5958-2 - 1991
- Matériels électriques destinés à être utilisés en présence de poussières combustibles. 2e partie : Méthodes d'essai. Section 2 : Méthode de détermination de la résistivité électrique des couches de poussière. Paris La Défense, Union Technique de l'Électricité - CEI 61241-2-2...