3. Lightning protection
Since the invention of the lightning rod by Benjamin Franklin (USA) and Jacques de Romas (France) in 1753, various lightning capture devices have been developed, and lightning protection has constantly evolved to improve its effectiveness.
In this part of the article, we consider the lightning conductor to be an essential element of lightning protection, and will first review the various models that have been developed, either empirically or based on knowledge of the physics of large air gap discharges and/or artificial lightning triggering experiments, to define the distance or volume of protection for these capture devices.
The next step is to assess the need for appropriate lightning protection, based on an overall lightning risk analysis. This analysis is designed to determine the need to protect buildings, structures and equipment connected to networks that may be affected by lightning.
...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Lightning protection
Bibliography
-
(1) - KRIDER (E.P.) - The earth's electrical environment. - Dans Physics of lightning. Studies in geophysics, National Academy Press, Washington, DC, p. 30-40 (1986).
-
(2) - RAKOV (V.A.), UMAN (M.A.) - Lightning physics and effects. - Cambridge University Press (2003).
-
(3)...
Also in our database
-
ROUSSEAU (A.), GARY (C.), BERGER (G.) - Foudre et protection des bâtiments. -
Websites
GAUVIN (D.) Storm chaser http://www.impact-orage.com/
Lightning protection recommendations and lightning handbook by ITU-T Study Group 5 http://www.itu.int/ITU-T/studygroups/com05/index.asp
Standards and norms
- Protection against lightning – Part 1: General principles - CEI 62305-1 - 2010
- Protection against lightning – Part 2: Risk management - CEI 62305-2 - 2010
- Protection against lightning – Part 3 : Physical damages to structures and life hazard - CEI 62305-3 - 2010
- Protection against lightning – Part 4 : Electrical and electronic systems within structures - CEI 62305-4 - 2010
- Protection of...
Regulations
Arrêté du 15 janvier 2008 relatif à la protection contre la foudre de certaines installations classées, NOR : DEVP0770817A, JORF n° 0097 du 24 avril 2008 (version abrogated on August 6, 2011)
Directory
Manufacturers – Suppliers – Distributors (non-exhaustive list)
Météorage http://www.meteorage.fr
Météo France http://www.meteofrance.com
Vaisala http://www.vaisala.fr
EUCLID (EUropean Cooperation for...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!