Ventilated curtain wall
Curtain walls
Article REF: C3604 V1
Ventilated curtain wall
Curtain walls

Author : Moïse RIOTTEAU

Publication date: August 10, 2010, Review date: March 4, 2015 | Lire en français

Logo Techniques de l'Ingenieur You do not have access to this resource.
Request your free trial access! Free trial

Already subscribed?

3. Ventilated curtain wall

The design is identical to that of the breathable curtain wall, except that in addition to the lower vents, there are also vents at the top, generally on the vertical side to prevent water ingress, or on the upper transom by punctual interruption of the glazing joints.

This technique complies with standard EN 13830 and DTU 33.1, and does not require a fogging test, since natural ventilation makes fogging unlikely.

The disadvantage is the greater risk of dust ingress, since there is air circulation. Glazing must therefore be cleaned more frequently.

The advantage lies in lower temperatures, as hot air is exhausted to the outside by convection.

In France, more and more products are breathable. In Germany, on the other hand, ventilated or even highly...