12. Acoustics
Laboratory and in situ test standards are available to verify
acoustic performance. However, it is important to draw the attention
of building owners and contractors to the technical limits of sound
insulation. Up to 35 dB of insulation, the design poses no problem
(by fitting suitable components, particularly glazing and other fillings).
At 38 dB, it becomes difficult, and particular attention must be paid
to sound bridges.
We sometimes see specifications of 40 dB, which is quite a feat
in the laboratory, but once on site, there's little chance of achieving
this performance. There are, however, solutions that can go much further:
a double-skin façade. A traditional curtain wall is used on the outside,
and 10 to 20 cm on the inside, a double sash or even a full-height
aluminium or PVC frame is installed. The breathable or ventilated
window technique is, in this sense, often an advantage, since...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Acoustics
Regulations
Article 111.15 of the French Construction and Housing Code.
Article 5 Circulaire du 13/12/1982 relative à la sécurité des
personnes en cas de travaux de réhabilitation ou d'amélioration des
bâtiments d'habitation existants.
DRT circular no. 95-07 of 14/4/1995 on workplaces. This text specifies,
among other things, the need to use safety glass in doors, adjacent
parts, lower parts of corridors below 1 m, and spandrels on...