3. AEV tests
The performance of curtain walls must be verified using a mock-up
on a test bench. NF EN 13-830 (product standard) and DTU 33.1 (May
2008) define the rules and criteria for testing. Tests are carried
out in accordance with standards NF EN 12 152 – 12 153 – 12 154 –
12 178 published in 2000 and 2002:
air: 5 classes ;
water: watertight up to normal pressure ;
Normal wind: deflection at 1/200 limited to 15 mm ;
Extreme wind: extreme pressure = as per DTU.
To carry out a test, it is necessary
to build a model representative of the proposed design or site. The
height can be limited to the height of the floor (distance between
2 common supports), since it is then possible...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
AEV tests
Regulations
Article 111.15 of the French Construction and Housing Code.
Article 5 Circulaire du 13/12/1982 relative à la sécurité des
personnes en cas de travaux de réhabilitation ou d'amélioration des
bâtiments d'habitation existants.
DRT circular no. 95-07 of 14/4/1995 on workplaces. This text specifies,
among other things, the need to use safety glass in doors, adjacent
parts, lower parts of corridors below 1 m, and spandrels on...