8. Air gap analysis
We often speak of a ventilated air space as the potential solution to a pathology whose cause lies in the condensation of water vapour. This stems implicitly from the common belief that wet linen lying outside dries faster in windy conditions.
A distinction is made between unventilated and ventilated air gaps. The following are considered :
unventilated, air gaps, either without contact with the outside (see § ), or air gaps where the surface area of the openings bringing them into contact with the outside is less than 500 mm2 per linear metre (ml) of facade;
The surface area of the openings that bring them into contact with the outside is between 500 and 1,500 mm2 per ml of facade (corresponding to a horizontal slot 5 cm long by 1 to 3 cm high).
In a chimney, the circulation (draught) of gases depends either...