6. Mechanical sizing and verification
The lines are subjected to different load cases and must be checked with the combination of load cases defined in the construction code.
The most commonly encountered load cases are: self-weight, normal operating conditions (pressure and temperature), proof test, vacuum purge, earthquake and climatic conditions (wind, snow, outside temperature, etc.).
The diameter of the internal piping system(s) is obtained by checking the pressure drops according to the operating conditions: flow rate, pressure, temperature, fluid density, and by limiting the flow velocity, particularly with oxygen (the rule usually used for gaseous oxygen is 30 m/s for a pressure less than or equal to 15 bar).
The diameter is estimated from the classic pressure drop formula...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Mechanical sizing and verification
Bibliography
Also in our database
-
BAUDOUY (B.), DEFRESNE (G.), DUTHIL (P.), THERMEAU (J.P.) - Transfert de chaleur à basse température. - [BE 9 812]...
Software tools
Pipestress or CEASAR; software for calculating industrial piping systems according to the major construction codes
Standards and norms
- Tuyauteries en oxygène et systèmes de tuyauterie - EIGA 13/12 -
- Nettoyage des équipements pour le service d'oxygène - EIGA 33/06 -
- Cryogenic containers – Cleanliness - NF EN 12300 - 1999
- Cryogenic containers – Methods for assessing thermal insulation performance - NF EN 12213 - 1999
- Cryogenic containers – Valves for cryogenic use - NF EN 1626 - 2008
- Tuyauteries industrielles...
Regulations
PED 97-23-CE Pressure Equipment Directive
Statistical and economic data
CryoComp Data material conductivity database
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!