10. Opening protection
On average, retail stores are closed to the public 60-65% of the
time (nights and weekends). During these closed periods, virtually
all refrigerated sales units remain loaded with foodstuffs. The main
exceptions are certain display cases for unpackaged fragile foodstuffs,
which are returned to cold storage or conservation cabinets.
The main thermal stress on the cabinet and its load comes from
the opening. This represents 70% to 75% of the heat balance of the
open cabinet, and therefore requires an equivalent amount of instant
cooling power.
Through the cabinet opening :
A...