Principle of different containment techniques (other than ICR)
Ion trapping techniques

Add to my library

P2648 V1 Article

Principle of different containment techniques (other than ICR)


Ion trapping techniques

Authors : Jean-Pierre SCHERMANN, Michel VEDEL

Publication date: June 10, 2006 | Lire en français

Add to my library Add to my library

Logo Techniques de l'Ingenieur You do not have access to this resource.
Request your free trial access! Free trial

Already subscribed?

2. Principle of different containment techniques (other than ICR)

2.1 Static trap

The simplest confinement device is a cylindrical capacitor with a thin conductive wire as the inner frame. The ions created inside the device execute complex trajectories in the logarithmic potential, as described by Hooverman and Knight. In principle, the duration of confinement is infinite for all ions having a non-zero tangential velocity at the time of their creation. However, collisions with the residual gas cause the ions to neutralize on the central electrode, which necessarily has a finite diameter. Ions can be ejected radially by the application of a destabilizing voltage between the armatures, and a small fraction of these can be focused on the entrance slit of a mass analyzer or directly on a detector. Under certain shape conditions imposed on the electrodes,...

You do not have access to this resource.
Logo Techniques de l'Ingenieur

Exclusive to subscribers. 97% yet to be discovered!

You do not have access to this resource. Click here to request your free trial access!

Already subscribed?


Ongoing reading
Principle of different containment techniques (other than ICR)

Article included in this offer

"Analysis and Characterization"

( 277 articles )

Complete knowledge base

Updated and enriched with articles validated by our scientific committees

Services

A set of exclusive tools to complement the resources

View offer details

Contenus associés

Sur le même sujet

Veille personnalisée : Inscrivez-vous !

Dans les ressources documentaires

Microanalyse X par sonde électronique - Principe et instrumentation

La microanalyse X à sonde électronique permet d’analyser le spectre caractéristique de rayons X généré da...

Mesure nucléaire non destructive dans le cycle du combustible. Partie 1

Cet article a pour objet la mesure nucléaire non destructive utilisée dans le cycle du combustible nucléa...

WhitePaper
17 November 2015
Génie industriel - 3 fiches pratiques

Découvrez les fiches pratiques éditées par Techniques de l'Ingénieur à travers 3 exemples à télécharger : Mettre en œuvre un projet PLM au sein de l’entreprise ...

Tous les livres blancs
Article GoSpectro, ou la spectroscopie accessible
2 November 2016
GoSpectro, ou la spectroscopie accessible

Ultra-portable au même titre que le smartphone qu\'il accompagne, GoSpectro démocratise la spectroscopie comme outil de contrôle et d\'analyse sur le terrain.

Toutes les actualités
Contact us