3. Experimental setup
A classic installation includes :
The pumping device used depends on the nature of the material to be deposited. If the material is not very sensitive to oxygen or nitrogen, pumping can be carried out by Roots pumps, which provide rapid evacuation and sufficient ultimate pressure (p " 1.5 × 10– 2 Pa). In most cases, however, deposits are sensitive to residual gases, and a good ultimate vacuum (p " 10–4 to 10– 5 Pa) is essential. To achieve this, oil diffusion pumps can be used, with a throttle valve between the chamber and the pump to limit the...
You do not have access to this resource.
Exclusive to subscribers. 97% yet to be discovered!
Already subscribed?
Log in!
Ongoing reading
Experimental setup
Bibliography
Specialist articles
-
(1) - MATTOX (D.M.) - Mechanisms of ion plating, International Conference on Ion Plating and Allied Techniques. - London, CEP. Consultants Edinburgh, p. 1-10, bibl. (52 réf.), 3-5 juil. 1979 (+ * Δ).
-
(2) - MACHET (J.), SAULNIER (P.), EZQUERRA (J.), GUILLE (J.) - Ion energy...
Manufacturers. Suppliers
(Non-exhaustive list)
Vacuum equipment and vacuum deposits in general
CIT Alcatel.
Balzers SA.
Eta Electrotech (Sté).
Leybold Heraeus Sogev SA.
As regards ionic deposition in particular, only Balzers, Leybold and Electrotech seem to be working in this field.
It should be noted that ULVAC, a Japanese company, sells ionic deposition systems. This company must have a branch...