3. Ion source characteristics

The gaseous ions are formed in the ionization source by a succession of processes which must be adapted to the nature of the sample, and which will help define the type of ionization source used. Ultimately, the ions are directed via a potential difference to the mass spectrometer's vacuum analyzer, either directly after their formation, or via an interface at atmospheric pressure. The different types of ion source used in organic mass spectrometry can be classified according to the four routes described in figure 6 . They can be identified in terms of :

  • gas-phase ionization source (channel a) ;

  • pneumatically assisted electrospray ionization (channel b);

  • ionization/desorption...

You do not have access to this resource.
Logo Techniques de l'Ingenieur

Exclusive to subscribers. 97% yet to be discovered!

You do not have access to this resource. Click here to request your free trial access!

Already subscribed?


Ongoing reading
Ion source characteristics

Article included in this offer

"Analysis and Characterization"

( 271 articles )

Complete knowledge base

Updated and enriched with articles validated by our scientific committees

Services

A set of exclusive tools to complement the resources

View offer details

Dans les ressources documentaires

Couplages chromatographiques avec la spectrométrie de masse. I

La chromatographie est une méthode séparative des différents constituants d'un mélange. La coupler, après...

Couplages chromatographiques avec la spectrométrie de masse. III

Le couplage de la chromatographie en phase liquide à la spectrométrie de masse (LC-MS) a connu plusieurs ...

Spectrométrie d’émission optique à source étincelle (partie 1)

Les techniques de spectrométrie optique (SEO) sont nombreuses et très largement utilisées dans le domaine...

Spéciation des actinides au moyen du rayonnement synchrotron

La spéciation est la connaissance du degré d’oxydation et de la nature du polyèdre de coordination d’un é...

Tous les livres blancs
Toutes les actualités
Contact us