3. Case study

3.1 Fan motor bearing fault

Here's how a diagnosis was carried out on a motorized fan unit at an incineration plant in the Paris region, driven at 2,420 rpm by a 300 kW motor and pulley-belt transmission.

  • The values measured during a periodic inspection show that, on the motor bearing on the pulley side, the alarm threshold defined for the global indicator "RMS speed" standardized to 10/1,000 Hz has been exceeded. The value of this global indicator, measured in the horizontal radial direction, has risen from 3.9 to 12.2 mm/s since the last collection, whereas it remains more or less stable on the other fan bearings and on the vertical radial measurements of the bearing in question.

...
You do not have access to this resource.
Logo Techniques de l'Ingenieur

Exclusive to subscribers. 97% yet to be discovered!

You do not have access to this resource. Click here to request your free trial access!

Already subscribed?


Article included in this offer

"Maintenance"

( 78 articles )

Complete knowledge base

Updated and enriched with articles validated by our scientific committees

Services

A set of exclusive tools to complement the resources

View offer details

Contenus associés

Sur le même sujet

Veille personnalisée : Inscrivez-vous !

Dans les ressources documentaires

Capteurs industriels de vibration

Dans le domaine industriel, on est souvent amené à mesurer la vibration des objets. Pour cela, on utilise...

Prévention des risques professionnels - Risques liés aux bruits et vibrations

Cet article est consacré aux bruits et aux vibrations, deux risques importants reconnus comme maladies pr...

WhitePaper
4 December 2018
Caméra thermique : FLIRGFx320

Caméra infrarouge pour la détection des gaz à sécurité intrinsèque. Description produit de deux pages

Tous les livres blancs
Article Des objets connectés fonctionnant sans pile
2 June 2023
Des objets connectés fonctionnant sans pile

Les appareils IoT d’intérieur ont toujours fonctionné sur batterie. Mais la société française Dracula Technologies a développé une solution originale de collect...

Toutes les actualités
Contact us