The fire safety regulations (articles DF) of June 25 1980 [TBA 3 004] define the purpose, principles and obligations of smoke ventilation in public-access buildings (ERP).

These provisions are specified, where applicable, by special provisions specific to each type of establishment. The purpose of this instruction is to set out the rules for the implementation of smoke extraction systems, by describing solutions which ensure :

  • smoke and fume extraction from stairways ;

  • smoke extraction from horizontal corridors ;

  • smoke extraction from premises accessible to the public.

This instruction does not exclude the possibility of adapting smoke control solutions to particular configurations or locations, provided equivalent results are obtained, and in particular :

  • satisfactory sweeping of the area concerned;

  • unhindered stratification and natural smoke movement.

Smoke extraction solutions must be compatible with each other.

You do not have access to this resource.
Logo Techniques de l'Ingenieur

Exclusive to subscribers. 97% yet to be discovered!

You do not have access to this resource. Click here to request your free trial access!

Already subscribed?


KEYWORDS

  |     |     |     |     |     |  

Ongoing reading
ERP fire safety - Technical Instruction 246 on smoke control

Article included in this offer

"Preparing for construction"

( 117 articles )

Complete knowledge base

Updated and enriched with articles validated by our scientific committees

Services

A set of exclusive tools to complement the resources

View offer details

Contenus associés

Sur le même sujet

Veille personnalisée : Inscrivez-vous !

Dans les ressources documentaires

Sécurité incendie des ERP - Instruction technique no 263 relative à la construction et au désenfumage des volumes libres intérieurs

  La présente Instruction Technique a pour objet de définir les règles de construction et les princ...

Sécurité incendie des ERP - Instruction technique relative à l'utilisation d'installations particulières

  Le règlement de sécurité contre les risques d’incendie et de panique dans les Établissements Rece...

Sécurité incendie des ERP - Instruction technique n 247 relative aux mécanismes de déclenchement des dispositifs de fermeture résistant au feu et de désenfumage

  Cette instruction technique est citée dans de nombreux articles sur les Établissements Recevant d...

Sécurité incendie dans les Immeubles de Grande Hauteur (IGH) - Instruction technique relative au désenfumage

  La réglementation incendie des Immeubles de Grande Hauteur (IGH) et des Immeubles de Très Grande ...

WhitePaper
4 December 2018
Caméra thermique : FLIRGFx320

Caméra infrarouge pour la détection des gaz à sécurité intrinsèque. Description produit de deux pages

Tous les livres blancs
Toutes les actualités
Contact us